Home / Products / Reverse Osmosis Membrane Elements / Brackish Water (BW) / BWRO Membrane High Rejection Series BW-8040-400HR
BW RO membrane elements are mainly used for brackish water desalination. They provide excellent, stable and consistent membrane performance for industrial water treatment systems.
Product Description
UltraClean BW reverse osmosis membrane elements are primarily used for brackish water desalination, providing excellent, stable and consistent membrane performance for industrial water treatment systems. The element operates at low pressure, providing a more cost-effective option for industrial-grade applications. For more difficult dissolved salts, such as TOC, SiO2, etc., it has a high removal rate. It is suitable for near-zero discharge of wastewater in the petroleum and petrochemical industries and boiler feed water in thermal power plants.
Membrane Features
Advanced membrane technology with innovative thin layer composite membrane design.
More consistent performance with less fouling requiring less frequent cleaning and change-outs.
100% dry-stored membrane maximizing shelf life.
Membrane Performance Specification
Active Area ft²(m²) | 400(37) |
Permeate Flow Rate GPD(m³/d) | 10500(40) |
Min Rejection(%) | 99.0 |
Average Rejection(%) | 99.5 |
Test conditions: inlet pressure 1.55 MPa (225 psi); inlet temperature 25°C (77°F); inlet water quality 2000ppm NaCl; inlet pH 8; recovery 15%.
Product Highlights
Stable performance and high rejection rate for organics
Low operating pressures, high flux and cost saving
Meet the demand for near zero discharge
About this item
HIGH QUALITY MEMBRANE:Features highest flow rates available to meet the water demands of both land and sea based desalinates, offering a high efficiency while providing a superior quality of water for your household or business to consume and enjoy.
FRESH TASTING WATER:The Reverse Osmosis Replacement Membrane cleans your water by removing heavy metals, inorganics and volatile organics and other harmful chemicals that produce distasteful and smelly odors.
Application
● Pure water system
● Chemical RO filtration
● Desalination of brackish water
● Food and beverage wastewater
● Power plant boiler make-up water
● Medical reverse osmosis filtration system
General Information
The first full tank of permeate should be discarded, DO NOT use this initial permeate for drinking water or food preparation.
Keep membrane moist at all times after initial wetting.
To stop growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
Operating and Cleaning Limits
Maximum Operating Pressure | 41 bar (600 psi) |
Maximum Operating Temperature | 45°C (113°F ) |
Maximum Element Pressure Drop | 1.0 bar (15psi) |
pH Range Continuous Operation | 2-11 |
pH Range Short-Term Cleaning | 1-13 |
Maximum Feed SDI(SDI15) | 5.0 |
Free Chlorine Tolerance | < 0.1 ppm |
Series Products
Number | Membrane Model |
01 | BW Series-Brackish Water RO Membranes UC BW-4040-82 |
02 | BW Series-Brackish Water RO Membranes UC BW-4040-82FR |
03 | BW Series-Brackish Water RO Membranes UC BW-4040-82LE |
04 | BW Series-Brackish Water RO Membranes UC BW-4040-82XFR |
05 | BW Series-Brackish Water RO Membranes UC BW-4040-82XLE |
06 | BW Series-Brackish Water RO Membranes UC BW-8040-82HRFR |
07 | BW Series-Brackish Water RO Membranes UC BW-8040-400FR/34 |
08 | BW Series-Brackish Water RO Membranes UC BW-8040-400FR |
09 | BW Series-Brackish Water RO Membranes UC BW-8040-400FRLE/34 |