UltraClean HRFR series high desalination reverse osmosis membrane element is one of the reverse osmosis membrane elements with the highest desalination rate, with a stable desalination rate of 99.7%. In general industrial and water treatment applications, stringent effluent quality requirements can be met with a primary reverse osmosis system. This series of 8-inch membrane elements has an effective membrane area of 37 square meters, which can not only maximize productivity, but also achieve accurate and predictable system design and operating flux. Meet higher water purification requirements at a lower cost. Available in 8-inch and 4-inch sizes.
Product Highlights
Stable performance and high rejection rate for organics
Low operating pressures, high flux and cost saving
Meet the demand for near zero discharge
Operating and Cleaning Limits
Maximum Operating Pressure | 41 bar (600 psi) |
Maximum Operating Temperature | 45°C (113°F ) |
Maximum Element Pressure Drop | 1.0 bar (15psi) |
pH Range Continuous Operation | 2-11 |
pH Range Short-Term Cleaning | 1-13 |
Maximum Feed SDI(SDI15) | 5.0 |
Free Chlorine Tolerance | < 0.1 ppm |
Notes
Permeate flow for individual elements may vary ±15 percent from the value specifed.
Active membrane area guaranteed ±4%.
Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater characteristics and operating conditions.
Performance Specification
Effective Membrane Area ft²(m²) | Stablized Rejection Rate(%) | Minimum Rejection rate(%) | Flux gpd(m³/d) |
400 (37) | 99.7 | 99.4 | 11500 (43.5) |
Test conditions: inlet pressure 1.55 MPa (225 psi); inlet temperature 25°C (77°F); inlet water quality 2000ppm NaCl; inlet pH 8; recovery 15%.